Construction Standards and Specifications
Isle of Wight County Public Utilities currently adheres to Hampton Roads Planning District Commission (HRPDC) standards. No variations from HRPDC standards for Utilities Design and construction are permitted unless specifically approved on a case-by-case basis in writing. Approval of site plans, project plans, conceptual designs or other submissions do not constitute approval to vary from these standards. For questions regarding reviews and inspections, please contact our Construction Team at 757-365-6275.
Standard Details
HRPDC standard details for use on site plans are available for download at Standard Details | Hampton Roads, VA. HRPDC details shall be utilized with the exception of the following for service connection details that specifically apply to Isle of Wight County:
WATER SERVICE CONNECTIONS:
Isle of Wight uses specific boxes that fit our meters and lids. Please note the differences below:

SEWER SERVICE CONNECTIONS:
Isle of Wight does not allow dual service connections. In addition, flexible couplings and other materials designed for temporary repair applications are not allowed. Areas with deeper sewer lines will require longer riser pipes. Please note the differences below:

PIPE BEDDING DETAILS
In addition to PDC standards, Isle of Wight County incorporates the following regarding backfilling for gravity sewer and pressurized pipe installations:
_Page_1.jpg?t=202608060219080)
Click here to download a copy
Pump Station Standards
Developments that propose new sewage operations in areas where existing facilities are not available or do not have additional capacity are required to install a pump station. Designs should be traditional wet-well in nature and be constructed in accordance with state and local guidelines. The Hampton Roads Sanitation District (HRSD) serves Isle of Wight County for pump station discharges, and should be coordinated with in the early stages of design. Contact the HRSD Development Services department by visiting their website or by emailing developrequest@hrsd.com. Program/_Pump Sta photo - Copy.jpg?t=202610191605190)
- Pump Station site plan
- General notes and specs
- Plan views (including auxilliary sections of both the building and the wet well)
- Foundation plans
- Electrical plans (including line diagrahms, notes and schematics)
- Details
- Fencing and landscaping if applicable
Backflow prevention and grease interceptors:
For more information on Backflow and our Fats, Oils, and Grease (FOG) program, visit our webpage here.
Construction Record Drawings
Also referred to as "As-Builts", construction record drawings are required to be submitted by the owner/developer at the end of the construction phase. These drawings are based on the approved plans and any contractor redlines, and denotes physical changes or modifications that were needed in the field during construction. Please see our guidelines below
As-Built Requirements - Isle of Wight County
Service Applications and Forms